● Function Mode

  • Function  Description
    To  assign  the  Message  Receiving  Mode  to  each  Function  Switch.


  • Option  or  Range  List
    None-  Default  setting  only.   

    Selective    Call-  Used  when  one  wants  to  the  pager  to  alert  upon  receipt  of  a  valid  2  tone  message. 

    Monitor    Mode  –  Allows  monitoring  of  the  selected  channel  and  the  G1  will  alert  upon  receiving  a  valid  2  tone  message. 

    Normal    Scan  –  Works  in  concert  with  Scan  List  Parameter  Setting  to  allow  automatic  scanning  of  up  to  eight  channels.    The  G1  will  un-squelch  upon  detection  of  signal  on  a  channel  .Upon  loss  of  signal    the  G1  will  begin  scanning  the  other  channels  in  the  Scan  List.

    Priority  Scan-  Works  in  concert  with  Scan  List  Parameter  Setting  to  allow  automatic  scanning  of  up  to  eight  channels.    The  G1  will  un-squelch  upon  detection  of  signal  on  a  channel,  but  will  periodically  scan  back  to  the  “Priority  Channel”  looking    for  signal.    If  no  Priority  Channel  activity  is  detected  the  G1  will  continue  to  play  audio  until  loss  of  signal  on  the  non-Priority  channel.  Upon  loss  of  signal  the  G1  will  begin  scanning  the  other  channels  in  the  Scan  List.   
    There  is  a  Priority  Channel  Check  Interval  setting  in  the  Scan  List  Parameter  Settings  that  can  be  adjusted  for  better  non-priority  channel  intelligibility.    The  setting  can  be  made  larger,  however  too  large  a  time  could  mean  a  2  tome  message  on  the  Priority  Channel  may  be  missed  or  not  stored. 

    Silent  Scan  -  Works  in  concert  with  Scan  List  Parameter  Setting  to  allow  automatic  scanning  of  up  to  eight  channels.    The  G1  will  un-squelch  only  upon  detection  of  a  valid  2  tone  message.  Upon  loss  of  signal  the  G1  will  begin  scanning  the  other  channels  in  the  Scan  List.  The  assumption  is  that  only  paging  channels  are  assigned  to  the  Scan  List  associated  with  this  Function  Mode.   

    Dual  Channel  Scan  –  This  Mode  allows  for  Priority  or  Normal  scanning  of  2  channels.     

    Channel  Scan-  A  feature  unique  to  the  G1  that  works  in  concert  with  the  Manual  Scan  Relative  Parameter  Setting.    It  allows  manual  selected  monitoring  of  any  of  the  channels  selected  in  the  Channel  Scan  List.  Up  to  64  channels  can  be  monitored.

    Free  Scan-  A  feature  unique  to  the  G1  that  works  in  concert  with  the  Manual  Scan  Relative  Parameter  Setting.  It  allows  the  manual  selection  of  channels  across  a  frequency  band.  Channel    increments  are  selectable  in  the  Manual  Scan  Relative  Parameter  Setting.